MODEL : CI-PC93
  • With overpressure protection, when the pressure in the gas path exceeds the pressure protection range, automatically cut off the gas path on both sides of the sensor chamber;

  • High precision pressure automatic compensation, reduce the impact of pressure on the measurement accuracy;

  • With over range protection, when the oxygen concentration is higher than the protection limit value, the device will automatically cut off the gas path on both sides of the sensor chamber, to avoid the sensor in the high oxygen concentration environment for a long time and affect its performance and life.

Principle: Electrochemical
Measuring range: 0~10/100/1000ppm/1/25.00% O2

Accuracy:
0.01~9.99ppm O2: ±5%FS
10.0~99.9ppm O2: ±3%FS
100~1000ppm O2: ±2%FS

Repeatability:
0.01~9.99ppm O2: ±2.5%FS
10.0~99.9ppm O2: ±1.5%FS
100~1000ppm O2: ±1%FS

Stability:
0.01~9.99ppm O2: ±2.5%FS/7d
10.0~99.9ppm O2: ±1.5%FS/7d
100~1000ppm O2: ±1%FS/7d

Response Time: T90<60s (25°C)
Power Supply: AC 100~240V, 50/60Hz
Communication: RS485(standard)/RS232(optional)
Ambient Temperature.: 0~+45°C
Ambient Humidity:<80%RH
Sample Gas Flow: 1~1.5L/min (recommended: 1.2L/min)
Sample Gas Pressure: Equipped with needle valve, within 35-210 kPa, ensure the flow is within 1-1.5L/min
Analog Signal: 1 group,4~20mA/0~20mA/0~1V/0~5V/0~10V/1~5V, can be set freely

Related products

CI-PC125 Online Oxygen Analyzer
CI-PC121 Online Oxygen Analyzer
CI-PC126 Online Oxygen Analyzer
CI-PC9260 Online Gas Chromatograph
CI-PC192 Flue Oxygen Analysis System
In-situ Flue Oxygen Analyzer (CI-PC191/-1)
Explosion-Proof In-situ Flue Oxygen Analyzer (CI-PC152)
High Altitude Oxygen Monitor (CI-PC89)
Oxygen Monitor (CI1300)
GNL-2100L Portable High Content Oxygen Analyzer
Online Oxygen Transmitter (CI-PC886)
High Content Oxygen Transmitter (CI-PC88)
Online Explosion-Proof High Content Oxygen Analyzer (CI-PC851-2)
Online Explosion-Proof High Content Oxygen Analyzer (CI-PC851-1)
Online Wall-Mounted High Content Oxygen Analyzer (CI-PC851)
Online High Content Oxygen Analyzer (CI-PC86)
Online High Content Oxygen Analyzer (CI-PC81)
Portable Oxygen Analyzer (CI-PC933)
CI-PC888/-1 Oxygen Transmitter
Online Explosion-Proof Oxygen Analyzer (CI-PC15-1)
Online Wall-mounted Oxygen Analyzer (CI-PC15)
Online Oxygen Analyzer (CI-PC11)
Online Oxygen Analyzer (CI-PC162)
Oxygen Transmitter (CI-PC983)
CI-PC951-2 Online Explosion-Proof Oxygen Analyzer
CI-PC951-1 Online Explosion-Proof Oxygen Analyzer
CI-PC951 Online Wall-mounted Oxygen Analyzer
CI-PC912 Online Oxygen Analyzer
Online Oxygen Analyzer (CI-PC962)
GNL-2100 Portable Oxygen/Nitrogen Analyzer
Portable Oxygen Analyzer (CI-PC13)
Portable Trace Oxygen Analyzer (CI-PC931/932)
Portable Trace Oxygen Analyzer (CI-PC93)
GNL-B1A Portable Trace Oxygen Analyzer
Oxygen/ Nitrogen Transmitter (CI-PC881)
Online Explosion-Proof Oxygen/Nitrogen Analyzer (CI-PC85-2)
CI-PC85-1 Online Explosion-Proof Oxygen/Nitrogen Analyzer
Online Wall Mounted Oxygen/Nitrogen Analyzer (CI-PC85)
Online Oxygen/Nitrogen Analyzer (P860)
GNL-6900 Online Wide Range Oxygen Analyzer
GNL-6800 Online Wide Range Oxygen Analyzer
GNL-120-1/-3 Online Oxygen Transmitter
CI-PC1208 Online Multi-channel Oxygen Analyzer
CI-PC1201 Online Multi-channel Oxygen Analyzer
Online Oxygen Analyzer (CI-PC128)
Online Oxygen Analyzer (CI-PC16)
Wide Area Oxygen Transmitter (CI-PC986)
Trace Oxygen Transmitter (GNL-B5/CI-PC981)
CI-PC95-2 Online Explosion-Proof Trace Oxygen Analyzer
CI-PC95-1 Online Explosion-Proof Trace Oxygen Analyzer
Online Wall-Mounted Trace Oxygen Analyzer (CI-PC95)
Online Trace Oxygen Analyzer (CI-PC96/PC961)
Online Trace Oxygen Analyzer (CI-PC91)
CI-PC90 Online Trace Oxygen Analyzer